Identification of Parameters Influencing the Vascular Structure Displacement in Fusion Imaging during Endovascular Aneurysm Repair - Université de Rennes Accéder directement au contenu
Article Dans Une Revue JVIR: Journal of Vascular and Interventional Radiology Année : 2019

Identification of Parameters Influencing the Vascular Structure Displacement in Fusion Imaging during Endovascular Aneurysm Repair

Résumé

Purpose - To quantify the displacement of the vascular structures after insertion of stiff devices during endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm and to identify potential parameters influencing this displacement. Materials and methods - A total of 50 patients from a single center undergoing EVAR were prospectively enrolled between January 2016 and December 2017. Fusion imaging was employed using the EndoNaut (Therenva, Rennnes, France) station through a 3-dimensional (3D)/2-dimensional (2D) technology synchronizing the 3D computed tomography scan to the live intraoperative fluoroscopy. The accuracy of the fusion roadmap was evaluated before deployment by conventional digital subtraction angiogram on a single plane (with different C-arm incidences). Results - The mean displacement error of the ostium of the lowest renal artery was 4.1 ± 2.4 mm (range, 0-11.7 mm), with a left/right displacement of 1.6 ± 1.7 mm (range, 0-6.9 mm) and a craniocaudal displacement of 3.5 ± 2.4 mm (range, 0-11.3 mm). The correction required for the ostium of the lower renal artery was mostly cranial and to the left. Multiple linear regression analysis revealed only the sharpest angle between the aneurysm neck and sac as the factor influencing the accuracy of fusion imaging. All other parameters did not show any correlation. Conclusions - This study identified the sources of fusion error after insertion of rigid material during EVAR. As the sharpest angulation between aneurysm neck and sac increases, the overall accuracy of the fusion might be affected.
Fichier principal
Vignette du fichier
Lalys-2019-Identification of Parameters Influencing the Vascular Structure Displacement-final.pdf (1.18 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02150190 , version 1 (08-07-2019)

Identifiants

Citer

Florent Lalys, Alexandre Barré, Moundji Kafi, Mohamed Benziane, Blandine Saudreau, et al.. Identification of Parameters Influencing the Vascular Structure Displacement in Fusion Imaging during Endovascular Aneurysm Repair. JVIR: Journal of Vascular and Interventional Radiology, 2019, 30 (9), pp.1386-1392. ⟨10.1016/j.jvir.2019.02.022⟩. ⟨hal-02150190⟩
93 Consultations
241 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More