[From image-guided radiotherapy to dose-guided radiotherapy]. - Université de Rennes Accéder directement au contenu
Article Dans Une Revue Cancer/Radiothérapie Année : 2011

[From image-guided radiotherapy to dose-guided radiotherapy].

Résumé

PURPOSE: In case of tumour displacement, image-guided radiotherapy (IGRT) based on the use of cone beam CT (tomographie conique) allows replacing the tumour under the accelerator by rigid registration. Anatomical deformations require however replanning, involving an estimation of the cumulative dose, session after session. This is the objective of this study. PATIENTS AND METHODS: Two examples of arc-intensity modulated radiotherapy are presented: a case of prostate cancer (total dose=80 Gy) with tomographie conique (daily prostate registration) and one head and neck cancer (70 Gy). For the head and neck cancer, the patient had a weekly scanner allowing a dose distribution calculation. The cumulative dose was calculated per voxel on the planning CT after deformation of the dose distribution (with trilinear interpolation) following the transformation given by a non-rigid registration step (Demons registration method) from: either the tomographie conique (prostate), or the weekly CT. The cumulative dose was eventually compared with the planned dose. RESULTS: In cases of prostate irradiation, the "cumulative" dose corresponded to the planned dose to the prostate. At the last week of irradiation, it was above the planned dose for the rectum and bladder. The volume of rectal wall receiving more than 50 Gy (V50) was 20% at the planning and 26% at the end of treatment, increasing the risk of rectal toxicity (NTCP) of 14%. For the bladder wall, V50 were 73% and 82%, respectively. In head and neck, the "cumulative" dose to the parotid exceeded the planned dose (mean dose increasing from 46 Gy to 54 Gy) from the 5th week of irradiation on, suggesting the need for replanning within the first 5 weeks of radiotherapy. CONCLUSION: The deformable registration estimates the cumulative dose delivered in the different anatomical structures. Validation on digital and physical phantoms is however required before clinical evaluation.
Fichier principal
Vignette du fichier
Cazoulat_From_image-guided_radiotherapy_to_dose-guided_radiotherapy.pdf (85.44 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

inserm-00699901 , version 1 (21-05-2012)

Identifiants

Citer

Guillaume Cazoulat, M. Lesaunier, Antoine Simon, Pascal Haigron, Oscar Acosta, et al.. [From image-guided radiotherapy to dose-guided radiotherapy].. Cancer/Radiothérapie, 2011, 15 (8), pp.691-8. ⟨10.1016/j.canrad.2011.05.011⟩. ⟨inserm-00699901⟩
297 Consultations
537 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More