Experimental validation of a new power line communication system for battery management - Université de Rennes Accéder directement au contenu
Communication Dans Un Congrès Année : 2014

Experimental validation of a new power line communication system for battery management

Résumé

A new Power Line Communication (PLC) solution over a DC powerline is presented for remote management of batteries. This solution rely on the well known Controller Area Network (CAN) protocol and is designed to be directly compatible with existing CAN controllers. The presented PLC-CAN system is a low complexity and low cost solution suitable for short and low power DC bus used in small scale autonomous systems. Simulations of the communication channel over the frequency range [0.5 - 10] MHz are conducted to validate the concept's feasibility. Experimental measurements on prototypes are then presented and show achievable data rates of 116 kbit/s.
Fichier non déposé

Dates et versions

hal-01058197 , version 1 (26-08-2014)

Identifiants

  • HAL Id : hal-01058197 , version 1

Citer

Jérémie Jousse, Nicolas Ginot, Christophe Batard, Elisabeth Lemaire. Experimental validation of a new power line communication system for battery management. PRIME 2014 - 10th Conference on Ph.D Research in Microelectronics and Electronics, Jun 2014, Grenoble, France. pp.1-4. ⟨hal-01058197⟩
100 Consultations
0 Téléchargements

Partager

Gmail Facebook X LinkedIn More