End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study - Biology of Cardiovascular Diseases Accéder directement au contenu
Article Dans Une Revue Critical Care Année : 2018

End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study

Résumé

BACKGROUND: In mechanically ventilated patients, an increase in cardiac index during an end-expiratory-occlusion test predicts fluid responsiveness. To identify this rapid increase in cardiac index, continuous and instantaneous cardiac index monitoring is necessary, decreasing its feasibility at the bedside. Our study was designed to investigate whether changes in velocity time integral and in peak velocity obtained using transthoracic echocardiography during an end-expiratory-occlusion maneuver could predict fluid responsiveness. METHODS: This single-center, prospective study included 50 mechanically ventilated critically ill patients. Velocity time integral and peak velocity were assessed using transthoracic echocardiography before and at the end of a 12-sec end-expiratory-occlusion maneuver. A third set of measurements was performed after volume expansion (500 mL of saline 0.9% given over 15 minutes). Patients were considered as responders if cardiac output increased by 15% or more after volume expansion. RESULTS: Twenty-eight patients were responders. At baseline, heart rate, mean arterial pressure, cardiac output, velocity time integral and peak velocity were similar between responders and non-responders. End-expiratory-occlusion maneuver induced a significant increase in velocity time integral both in responders and non-responders, and a significant increase in peak velocity only in responders. A 9% increase in velocity time integral induced by the end-expiratory-occlusion maneuver predicted fluid responsiveness with sensitivity of 89% (95% CI 72% to 98%) and specificity of 95% (95% CI 77% to 100%). An 8.5% increase in peak velocity induced by the end-expiratory-occlusion maneuver predicted fluid responsiveness with sensitivity of 64% (95% CI 44% to 81%) and specificity of 77% (95% CI 55% to 92%). The area under the receiver operating curve generated for changes in velocity time integral was significantly higher than the one generated for changes in peak velocity (0.96 ± 0.03 versus 0.70 ± 0.07, respectively, P = 0.0004 for both). The gray zone ranged between 6 and 10% (20% of the patients) for changes in velocity time integral and between 1 and 13% (62% of the patients) for changes in peak velocity. CONCLUSIONS: In mechanically ventilated and sedated patients in the neuro Intensive Care Unit, changes in velocity time integral during a 12-sec end-expiratory-occlusion maneuver were able to predict fluid responsiveness and perform better than changes in peak velocity.
Fichier principal
Vignette du fichier
s13054-017-1938-0.pdf (540.76 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

inserm-02468918 , version 1 (06-02-2020)

Identifiants

Citer

Delphine Georges, Hugues de Courson, Romain Lanchon, Musa Sesay, Karine Nouette-Gaulain, et al.. End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study. Critical Care, 2018, 22 (1), pp.32. ⟨10.1186/s13054-017-1938-0⟩. ⟨inserm-02468918⟩

Collections

INSERM CNRS U1034
63 Consultations
49 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More