Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass - Biology of Cardiovascular Diseases Accéder directement au contenu
Article Dans Une Revue JAMA Cardiology Année : 2017

Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass

Sandrine Grosjean
  • Fonction : Auteur
Julie Boyer
  • Fonction : Auteur
Claude Girard
  • Fonction : Auteur

Résumé

Importance: Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective: To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, setting, and participants: Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions: Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main outcomes and measures: Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results: Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, -7% [95% CI, -17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Conclusions and relevance: Among patients with low ejection fraction who were undergoing coronary artery bypass grafting with cardiopulmonary bypass, levosimendan compared with placebo did not result in a significant difference in the composite end point of prolonged catecholamine infusion, use of left ventricular mechanical assist device, or renal replacement therapy. These findings do not support the use of levosimendan for this indication. Trial registration: EudraCT Number: 2012-000232-25; clinicaltrials.gov Identifier: NCT02184819.

Dates et versions

hal-03931955 , version 1 (10-01-2023)

Identifiants

Citer

Bernard Cholley, Thibaut Caruba, Sandrine Grosjean, Julien Amour, Alexandre Ouattara, et al.. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass. JAMA Cardiology, 2017, 318 (6), pp.548. ⟨10.1001/jama.2017.9973⟩. ⟨hal-03931955⟩
33 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More