Influence of the synthesis parameters on the efficiency of fluorescent ion-imprinted polymers for lead detection - Matériaux Polymères Interfaces Environnement Marin Accéder directement au contenu
Article Dans Une Revue Reactive and Functional Polymers Année : 2022

Influence of the synthesis parameters on the efficiency of fluorescent ion-imprinted polymers for lead detection

Résumé

New fluorescent ion-imprinted polymers (IIPs) specific for Pb(II) detection were synthesized by precipitation polymerization. The fluorescent activity of the IIPs was provided by a fluorescent functional monomer, ANQ-ST, based on the chelating 5-amino-8-hydroxyquinoline moiety coupled to anthracene and to a styrenic group. Various synthesis parameters were tested: metal/functional monomer ratio, polymerization solvent and crosslinker (ethyleneglycol dimethacrylate, EGDMA, or divinylbenzene, DVB). The characterization of the different IIPs was carried out by solid-state 13 C NMR spectroscopy, to analyse the structure of the polymers and to attest the integration of the ANQ-ST in the polymer matrix, and by scanning electron microscopy and nitrogen adsorption/desorption experiments, to study the morphology of the prepared materials. After characterization, the IIPs and their corresponding non-imprinted polymer (NIPs) were subjected to various fluorescence studies, in order to conclude on the influence of the synthesis parameters onto the polymer properties. The results demonstrated that the IIP synthesized with a metal/functional monomer ratio of 0.42 in DMSO/MeOH (1:1, v/v) and using EGDMA as a crosslinker was very sensitive to the presence of Pb(II) ions and almost not to that of the other tested ions (Ag(I), Na(I), Ca(II), Cd(II), Co(II), Cu(II) and Zn(II)), even when they were introduced in high excess. Calibration curves were performed in various matrices: ultra-pure water, buffered water at pH 7.0 and 8.1, seawater, tap water. They highlighted the low impact of the tested matrices onto the detection and allowed to determine a limit of detection of 2.4 µg/L and a linear range of 8.0-50 µg/L. Finally, the very good recovery obtained in natural samples emphasized the potential for the synthesized IIP to detect Pb(II) in natural waters.
Fichier principal
Vignette du fichier
rene et al (1).pdf (1.94 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03619676 , version 1 (25-03-2022)

Identifiants

Citer

William René, Véronique Lenoble, Katri Laatikainen, Bruno Viguier, Catherine Branger. Influence of the synthesis parameters on the efficiency of fluorescent ion-imprinted polymers for lead detection. Reactive and Functional Polymers, 2022, 170, pp.105134. ⟨10.1016/j.reactfunctpolym.2021.105134⟩. ⟨hal-03619676⟩
63 Consultations
54 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More